The T-200 is a 100 Ohm platinum based RTD, designed for accurate wide range temperature measurements outside the range of the thermistor probes. Met One Instruments’ temperature sensors are precision, extended-range thermistor devices that accurately measures ambient air temperature in field settings.
The T-200 mounts in both the 076B and 5980 Radiation Shields
This precise performance is a benefit of the sensors’ high resistance sensitivity, which eliminates problems associated with line lead length, noisy environments, and poor connections.
Features
l Rapid response time; 10 seconds in still air
l Calibration traceable to NIST
l Interchangeable without recalibration
l High resistance values to minimize signal line resistance
l ‘Free air’ suspension of thermistor bead
Temperature: -50° to +50° C (-58 to +122° F)
Optional Calibrations: -50°C to +70°C or -40°C to +60°C
(-58°F to +158°F or -40°F to +140°F)
Sensitivity: Alpha 0.00385 +/- 0.00002 Ohm/ohm/deg C
Nominal Resistance: 100 ohm +/- 0.1 ohm resistance (Ro)
Time Constant: 45 sec, approx. in moving air
Accuracy: +/- 0.1°C (0.18°F) throughout the range, PSD compliant
Configuration: 4 Wire Connection
Connection: 8” pigtails (for use with 076B Radiation Shield)
Cable: P/N 1734 For use with 5980 Naturally Aspirate Shield
Requires P/N 10418 Adapter Plate
Three lengths available, 5M/16Ft, 12M/40Ft 25M/82Ft