System Introduction:
The AST1000X/ type reference radiation station is a new fully automatic sun tracking system following the "Background Radiation Network (BSRN)" organized by WMO, which automatically measures the global radiation (GHI), direct radiation (DNI) and Radiation components such as scattered radiation (DIFF), which can calculate the sunshine duration, are higher standards and requirements for solar radiation. As my country's radiation measurement benchmark, it is used for calibration of solar radiation data from conventional meteorological stations and NASA satellite data. It can adapt to the business needs of the national climate monitoring network, meet the requirements of high precision and high stability of observation data, and can also be used for solar energy. Power forecast. AST1000X is suitable for sandstorm weather and industrial observation maintained by non-professionals.
The system adopts the traditional automatic sun tracker equipped with GPS and solar positioning probe, which meets the technical requirements of the International Radiation Background Observation Network, and accurately measures solar radiation, direct radiation and sky scattered radiation. It can also provide observations of other radiation parameters such as sky long-wave radiation, net radiation, and sunshine hours according to user requirements. As a general requirement for field observations, the system recommends users to join various meteorological observations: measure wind speed and direction, air temperature and humidity, atmospheric pressure and precipitation.
System Features:
It can display data in real time and receive data regularly.
Send data in real time and download data automatically and regularly, without the need for personnel to collect data.
A variety of data transmission methods, such as GSM, GPRS/CDMA, satellite, etc.
The output data is in tabular format, which is easy to be called under Excel and various data processing software and database software
Rugged Datalogger CR1000 Specifications
-NOTE- Additional specifications are listed in the CR1000 Specifications Sheet.
Operating Temperature Range
-25° to +50°C (standard)
-55° to +85°C (extended)
Analog Inputs 16 single-ended or 8 differential (individually configured)
Pulse Counters 2
Voltage Excitation Terminals 3 (VX1 to VX3)
Communications Ports
CS I/O
RS-232
Parallel peripheral
Switched 12 Volt 1 terminal
Digital I/O
Certain digital ports can be used to count switch closures.
8 I/Os or 4 RS-232 COM
I/O ports can be paired as transmit and receive for measuring smart serial sensors.
Input Limits ±5 Vdc
Analog Voltage Accuracy ±(0.06% of reading + offset) at 0° to 40°C
ADC 13-bit
Power Requirements 9.6 to 16 Vdc
Real-Time Clock Accuracy ±3 min. per year (Correction via GPS optional.)
Internet Protocols FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP
Communication Protocols PakBus, Modbus, DNP3, SDI-12, SDM
Warranty 3 years
Battery-backed SRAM for CPU Usage & Final Storage 4 MB
Idle Current Drain, Average < 1mA (@ 12 Vdc)
Active Current Drain, Average
1 mA (1 Hz sample rate @ 12 Vdc without RS-232 communication)
16 mA (100 Hz sample rate @ 12 Vdc without RS-232 communication)
28 mA (100 Hz sample rate @ 12 Vdc with RS-232 communication)
Dimensions
23.8 x 10.1 x 5.4 cm (9.4 x 4.0 x 2.1 in.)
25.2 x 10.2 x 7.1 cm (9.9 x 4.0 x 2.8 in.) with CFM100 or NL116 attached
Weight 1.0 kg (2.1 lb)
HygroVUE10 Digital Temperature and Relative Humidity Sensor with M12 Connector
Sensing Element: SHT35 modified by Campbell Scientific
Communication Standard : SDI-12 V1.4 (responds to a subset of commands)
Supply Voltage: 7 to 28 Vdc
EMC Compliance: Tested and conforms to IEC61326:2013.
Standard Operating Temperature Range: -40° to +70°C
Main Housing Material: UV stable, white PET-P
Electronics Sealing Classification: IP67
Sensor Protection: Outer glass-filled polypropylene cap fitted with a stainless-steel mesh dust filter with nominal pore size of < 30 µm. The sensor element has a PTFE protective film with a filtration efficiency of > 99.99% for particles of 200 nm or larger size.
Sensor Connector: M12, male, 4-pole, A-coded
Cable: Polyurethane sheathed, screened cable, nominal diameter 4.8 mm (0.19 in.)
Field-Replaceable Chip or Recalibrate: Field-replaceable chip
Sensor Cap Diameter: 12.5 mm (0.5 in.)
Body Diameter at Connector: 18 mm (0.7 in.)
Length: 180 mm (7.1 in.) without cable fitted
Sensor Body Weight: 50 g (1.8 oz)
Weight: 250 g (8.8 oz) with 5 m (16.4 ft) cable
Relative Humidity
Measurement Range: 0 to 100% RH
Accuracy :-NOTE- The accuracy figures quoted are the 95% confidence limits relative to factory standards.
±1.5% (at 25°C, over the range 0 to 80% RH)
±2% (at 25°C, over the range 80 to 100% RH)
Short-Term Hysteresis: < ±1% RH
Additional Errors at Other Temperatures: < ±1% RH (over -40° to +60°C)
Long-Term Stability: ±0.5% per year (maximum drift in clean air conditions)
Reported Resolution: 0.001% RH
Repeatability: 0.05% RH (3σ noise level)
Response Time with Filter: 8 s (63% response time in air moving at 1 m/s)
Air Temperature
Measurement Range: -40°C to +70°C
-NOTE-: The accuracy figures quoted are the 95% confidence limits relative to factory standards.
Accuracy :±0.2°C (over the range -40 to +70°C)
±0.1°C (over the range 20 to 60°C)
Long-Term Drift: < 0.03°C per year
Reported Resolution:0.001°C
Repeatability: 0.04°C (3σ noise level)
Response Time with Filter: < 130 s (63% response time in air moving at 1 m/s)
Calibration Traceability :NIST and NPL standards
Maximum Current Drain
Quiescent: 50 µA
During Measurement: 0.6 mA (takes 0.5 s)
EQ08-S Radiation Sensor
AST-02&03 Sun Tracker
DN5 & DN5-E Direct Radiation Sensors
For more technical parameters, please leave a message