AST-1000X Automatic Sun Tracking Monitoring System

System Introduction:The AST1000X/ type reference radiation station is a new fully automatic sun tracking system following the "Background Radiation Network (BSRN)" organized by WMO, which au

  • Product Name:AST-1000X Automatic Sun Tracking Monitoring System
  • Model:AST-1000X
  • Country:AU

System Introduction:

The AST1000X/ type reference radiation station is a new fully automatic sun tracking system following the "Background Radiation Network (BSRN)" organized by WMO, which automatically measures the global radiation (GHI), direct radiation (DNI) and Radiation components such as scattered radiation (DIFF), which can calculate the sunshine duration, are higher standards and requirements for solar radiation. As my country's radiation measurement benchmark, it is used for calibration of solar radiation data from conventional meteorological stations and NASA satellite data. It can adapt to the business needs of the national climate monitoring network, meet the requirements of high precision and high stability of observation data, and can also be used for solar energy. Power forecast. AST1000X is suitable for  sandstorm weather and industrial observation maintained by non-professionals.

The system adopts the traditional automatic sun tracker equipped with GPS and solar positioning probe, which meets the technical requirements of the International Radiation Background Observation Network, and accurately measures solar radiation, direct radiation and sky scattered radiation. It can also provide observations of other radiation parameters such as sky long-wave radiation, net radiation, and sunshine hours according to user requirements. As a general requirement for field observations, the system recommends users to join various meteorological observations: measure wind speed and direction, air temperature and humidity, atmospheric pressure and precipitation.


System Features:

It can display data in real time and receive data regularly.

Send data in real time and download data automatically and regularly, without the need for personnel to collect data.

A variety of data transmission methods, such as GSM, GPRS/CDMA, satellite, etc.

The output data is in tabular format, which is easy to be called under Excel and various data processing software and database software


Rugged Datalogger CR1000 Specifications

-NOTE-     Additional specifications are listed in the CR1000 Specifications Sheet.

Operating Temperature Range       

-25° to +50°C (standard)

-55° to +85°C (extended)

Analog Inputs      16 single-ended or 8 differential (individually configured)

Pulse Counters      2

Voltage Excitation Terminals      3 (VX1 to VX3)

Communications Ports   

CS I/O

RS-232

Parallel peripheral

Switched 12 Volt      1 terminal

Digital I/O        

Certain digital ports can be used to count switch closures.

8 I/Os or 4 RS-232 COM

I/O ports can be paired as transmit and receive for measuring smart serial sensors.

Input Limits     ±5 Vdc

Analog Voltage Accuracy       ±(0.06% of reading + offset) at 0° to 40°C

ADC      13-bit

Power Requirements      9.6 to 16 Vdc

Real-Time Clock Accuracy       ±3 min. per year (Correction via GPS optional.)

Internet Protocols       FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP

Communication Protocols       PakBus, Modbus, DNP3, SDI-12, SDM

Warranty     3 years

Battery-backed SRAM for CPU Usage & Final Storage      4 MB

Idle Current Drain, Average       < 1mA (@ 12 Vdc)

Active Current Drain, Average        

1 mA (1 Hz sample rate @ 12 Vdc without RS-232 communication)

16 mA (100 Hz sample rate @ 12 Vdc without RS-232 communication)

28 mA (100 Hz sample rate @ 12 Vdc with RS-232 communication)

Dimensions     

23.8 x 10.1 x 5.4 cm (9.4 x 4.0 x 2.1 in.)

25.2 x 10.2 x 7.1 cm (9.9 x 4.0 x 2.8 in.) with CFM100 or NL116 attached

Weight      1.0 kg (2.1 lb)


HygroVUE10 Digital Temperature and Relative Humidity Sensor with M12 Connector

Sensing Element       SHT35 modified by Campbell Scientific

Communication Standard   SDI-12 V1.4 (responds to a subset of commands)

Supply Voltage  7 to 28 Vdc

EMC Compliance Tested and conforms to IEC61326:2013.

Standard Operating Temperature Range     -40° to +70°C

Main Housing Material   UV stable, white PET-P

Electronics Sealing Classification    IP67

Sensor Protection    Outer glass-filled polypropylene cap fitted with a stainless-steel mesh dust filter with nominal pore size of < 30 µm. The sensor element has a PTFE protective film with a filtration efficiency of > 99.99% for particles of 200 nm or larger size.

Sensor Connector  M12, male, 4-pole, A-coded

Cable  Polyurethane sheathed, screened cable, nominal diameter 4.8 mm (0.19 in.)

Field-Replaceable Chip or Recalibrate   Field-replaceable chip

Sensor Cap Diameter      12.5 mm (0.5 in.)

Body Diameter at Connector  18 mm (0.7 in.)

Length       180 mm (7.1 in.) without cable fitted

Sensor Body Weight 50 g (1.8 oz)

Weight       250 g (8.8 oz) with 5 m (16.4 ft) cable

Relative Humidity

Measurement Range       0 to 100% RH

Accuracy       -NOTE- The accuracy figures quoted are the 95% confidence limits relative to factory standards.

±1.5% (at 25°C, over the range 0 to 80% RH)

±2% (at 25°C, over the range 80 to 100% RH)

Short-Term Hysteresis     < ±1% RH

Additional Errors at Other Temperatures     < ±1% RH (over -40° to +60°C)

Long-Term Stability        ±0.5% per year (maximum drift in clean air conditions)

Reported Resolution 0.001% RH

Repeatability     0.05% RH (3σ noise level)

Response Time with Filter       8 s (63% response time in air moving at 1 m/s)

Air Temperature

Measurement Range       -40°C to +70°C

-NOTE- The accuracy figures quoted are the 95% confidence limits relative to factory standards.

Accuracy       ±0.2°C (over the range -40 to +70°C)

±0.1°C (over the range 20 to 60°C)

Long-Term Drift       < 0.03°C per year

Reported Resolution0.001°C

Repeatability     0.04°C (3σ noise level)

Response Time with Filter       < 130 s (63% response time in air moving at 1 m/s)

Calibration Traceability NIST and NPL standards

Maximum Current Drain

Quiescent  50 µA

During Measurement      0.6 mA (takes 0.5 s)


EQ08-S Radiation Sensor

AST-02&03 Sun Tracker

DN5 & DN5-E Direct Radiation Sensors