Overview:
DJ-500X Series Tipping Bucket Flow Gauge has a built-in tipping bucket mechanical bi-stable mechanism, which is a kind of positive displacement flow meter. It is mainly used in the monitoring of surface and underground runoff with no pressure, low water level and low water flow.
Benefits and Features:
Use the tipping bucket type bi-stable mechanism, which has good stability and easy maintenance;
The tipping bucket flow meter is made of stainless steel, which is suitable for long-term use in harsh outdoor environments;
The use of adjustable feet can adapt to the uneven environment in the field;
The data logger has passed the IP67 test and is suitable for deployment outdoors;
The power supply of the data logger is simple, using CR-2032 3V lithium battery, no need to set up solar panels and batteries in the field;
Suitable for monitoring surface runoff, tree trunk interception and other special occasions.
Tipping Bucket Flow Gauge | |||||
DJ-5001 | DJ-5002 | DJ-5003 | DJ-5004 | DJ-5005 | |
Sensor type | Tipper with magnetic reed switch | ||||
Output signal | Pulse signal | ||||
Bucket Capacity | 50ml | 100ml | 500ml | 1000ml | 1000ml/50ml |
Size | L28*W17*H15 cm | L36*W17*H22 cm | L41*W20*H23 cm | L42*W24*H26 cm | L46*W26*H35 cm |
Inlet pipe diameter | 19mm | 19mm | 110mm | 110mm | 110mm |
Weight | 2kg | 2.5kg | 5.4kg | 7.9kg | 9.2kg |
Material | SUS304 Stainless Steel | ||||
Datalogger | |||||
Temperature measurement range | -20~+70℃ | ||||
Temperature Measurement Accuracy | ±0.53℃(0~50℃) | ||||
Temperature resolution | 0.14℃(25℃) | ||||
Temperature response time (in air) | 10mins,Typical 90%(2m/s air flow) | ||||
Logging Resolution | 1.0s | ||||
Operating Temperature | -20~+70℃ | ||||
Power | CR-2032 3V Lithium battery, typically can be used for 1 year | ||||
Memory | 64KB (16K~23K for data logging, 25K~30K for data and temperature logging) | ||||
Material | Polypropylene housing; stainless steel screws; Buna O-rings, PVC cable insulation | ||||
Weight | 50g | ||||
Size | 71×33×23mm |