Soil moisture content profiles down to 1m
Dual purpose – installed and portable
Uses access tubes for easy probe insertion and removal
SDI-12 interface option available
No other soil moisture probe system enables you to monitor your soil water profiles with such ease and flexibility. Install an access tube into the soil, insert the PR2 Profile Probe and press the HH2 [Read] button to display an instantaneous reading, or connect the PR2 to a data logger (GP2 or DL6) and leave the system to record soil moisture changes over time.
The PR2 soil moisture probe is built around patented sensing technology which provides unprecedented performance in all soil types, with minimal influence from either salinity or temperature. The PR2/4 model measures soil moisture at 4 depths down to 40 cm – the PR2/6 measures at 6 depths down to 100 cm.
Both analogue and SDI-12 interfaces are available for the PR2.
Highly reliable field-proven instrument
Soil moisture content – not just trends
Out of the box solution – supplied with calibrations for common soil types
Portable meter option for multi-site measurement
The PR2 Profile Probe is available in two sizes to measure to a depth of 40 cm or 100 cm.
The PR2/4 has sensing elements at 10/20/30/40 cm
The PR2/6 has sensing elements at 10/20/30/40/60 and 100 cm
HH2 Meter
The HH2 is a versatile readout unit that provides an easy and convenient way to display and store readings from Profile Probes. With the HH2 and PR2 combination, a probe can be moved from access tube to access tube, enabling large amounts of soil moisture data to be collected at multiple sites.
Data Logging
Profile Probes are available with analogue or SDI-12 outputs.
For the analogue version, order PR2/4 or PR2/6.
For the SDI-12 interface version, order PR2/4-SDI-12 or PR2/6-SDI-12.
Please note that analogue and SDI‐12 probes cannot be mixed on the same cable system
Loggers for analogue Profile Probes
Delta-T offers a choice of two data suitable data loggers. Both have dedicated PR2 Profile Probe input channels and connectors:
The DL6 Data Logger can log one PR2/6 or one PR2/4 Profile Probe
The GP2 Data Logger can log up to two PR2/6s or three PR2/4s
Loggers for SDI-12 Profile Probes
The PR2 SDI‐12 is ideally matched to the SDI‐12 enabled GP2 Data Logger. Many SDI-12 Profile Probes can be connected to a single GP2 (actual number depends on cable length, power, and other considerations).
Measurement Volumetric water content
Accuracy ± 0.04 m3.m-3 (4%)
With soil-specific calibration
Soil moisture measurement range Full accuracy over:
0 to 0.4 m3.m-3
Full range : 0 to 1.0 m3.m-3
Salinity range 50 to 400 mS.m-1
Salinity errors included in calibration
Temperature range Full accuracy over: 0 to 40°C
Output (ANALOGUE) 0 to 1.0 V differential PR2/6: x6 outputs, PR2/4: x4
Power requirement (ANALOGUE) 5.5-15 V,
PR2/6: ~120 mA for 1s
PR2/4: ~80 mA for 1s
Minimum 7.5 V with 100 m cable
Sleep curren t<2 mA at 12 V DC
Environmental IP67 (when installed in access tube)
Sample volume -95% sensitivity within a cylinder of diameter 200mm
Sample volume is weighted towards soil immediately surrounding the rods
Dimensions and weight PR2/6: length 1350 mm
PR2/4: length 750 mm
Both: 25.4 mm diameter
PR2/6: weight 1.2 kg
PR2/4: weight 0.8 kg
Sensor calibrations Individual sensors are interchangeable
Recalibration advised every 3 years (depending on use)
Soil calibrations Generalised Mineral and Organic soil calibrations are suppl ied