ONSET HOBO UX120-018 Plug Load Data Logger

OverviewOnset's HOBO Plug Load Data Logger is a high-accuracy, easy-to-deploy data logger that measures and records the power and energy consumption of 120V plug loads from office equipment, vendi

  • Product Name:ONSET HOBO UX120-018 Plug Load Data Loggerr
  • Model:UX120-018
  • Maunufactor:Onset
  • Country:USA

Overview

Onset's HOBO Plug Load Data Logger is a high-accuracy, easy-to-deploy data logger that measures and records the power and energy consumption of 120V plug loads from office equipment, vending machines, and other devices.

Accurate and Rugged

The UL certified logger provides 0.5% measurement accuracy with a measurement resolution of 1 watt, making it an ideal choice for building audits where detailed energy use data is required. The rugged housing is designed to withstand the rigors of real-world handling, providing reliable performance despite bumps, drops, and use under desks.

Highlighted Features

  • 0.5% measurement accuracy enables more reliable plug load energy data

  • "Meter Mode" provides instant viewing of real-time plug load variables

  • Provides time-stamped and totalized load data for detailed energy analysis

  • Large memory enables faster logging intervals for more comprehensive plug load profiles

  • Battery back-up ensures logged data remains intact in the event of a power outage or load failure

  • Full-featured LCD display provides visual diagnostics for easy deployment

  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

In what environment does this data logger operate?

This data logger operates in an indoor environment.

What measurements does this data logger support?

The UX120-018 data logger supports the following measurements: AC Current, AC Voltage, Amps (A), Kilowatt Hours (kWh), Power Factor (PF), Volt-Amps (VA), Volts (V), Watt Hours (Wh) and Watts (W)


Note: The UX120-018 logger is intended for use on 15 AMP circuits (NEMA 5-15P) with a working voltage of 120V AC ±10% at 50/60Hz and a max power of 1800W.

  • Indoor use only

  • Insulation category 2

RMS Voltage Accuracy:

0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle

RMS Current Accuracy:

0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle

Active Power Accuracy:

0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle

Active Energy Accuracy:

0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle

Power Factor Accuracy:

±0.02

Drift:

Up to 0.5% typical within 1 year

Resolution:

Volts, rms10mVAmps, rms0.1mAActive Power10mW down to 1 watt loads @ 120VACApparent Power10mVAPower Factor0.01 PF

Operating Environment:

Logging: 5° to 40°C (41° to 104°F); 0 to 95% RH (non-condensing), up to 2,000 m (6,562 ft) altitude

Operating Modes:

Meter or logging when launched with HOBOware

Logging Rate:

1 second to 18 hours, 12 minutes, 15 seconds

Statistics Sampling Rate:

60 Hz or 16.67 mS single-cycle

Memory Modes:

Wrap when full or stop when full

Start Modes:

Immediate, push button, date & time, or next interval

Stop Modes:

When memory full, push button, or date & time

Restart Mode:

Push button

Time Accuracy:

±1 minute per month at 25°C (77°F), see Plot A

Power Source:

Line-powered with 0.92 m (3 ft) AC power cord or two AAA 1.5 V alkaline batteries, user replaceable

Battery Life:

2 years with line power; 6 months battery only (no line power) with logging rate of 1 minute or greater operating at 25°C (77°F)

Memory:

4 MB (1.4 million measurements, maximum)

Download Type:

USB 2.0 interface

Full Memory Download Time:

Approximately 1.5 minutes

LCD:

LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range

Size:

13.97 x 7.62 x 4.75 cm (5.5 x 3 x 1.87 in.)

Weight:

230.8 g (8.14 oz)

Ratings:

IP50;
UL Listed; UL Listed to Canadian safety standards

Calibration:

This device has been calibrated using equipment that has been tested in accordance with ANSI C12.20 0.5%.